Item |
Contents |
Criteria |
1 |
Model |
HCX-D131 |
8S- 80A/50A working current |
2 |
Voltage |
Charging voltage |
28.8V |
3 |
Current |
Maximal continuous charging current |
20A/50A |
Maximal continuous discharging current |
80A/50A |
Current consumption |
≤20μA |
4 |
Overcharge Protection |
Over charge detection voltage |
3.6V~3.9V(Adjustable) |
Over charge detection delay time |
0.5S~2S |
Over charge release voltage |
3.5V~3.8V(Adjustable) |
5 |
Over Discharge Protection |
Over discharge detection voltage |
2.0V~2.5V(Adjustable) |
Over discharge detection delay time |
50~200mS |
Over discharge release voltage |
2.0V~2.5V(Adjustable) |
6 |
Over Current Protection |
Over current detection voltage |
0.1V~0.2V(Adjustable) |
Over current detection current |
Adjustable |
Detection delay time |
5~20mS |
Release condition |
Cut load,automatically recover |
7 |
Short Circuit Protection |
Detection condition |
Exterior shot circuit |
Detection delay time |
200~500uS |
Release condition |
Cut load,automatically recover |
8 |
Balance/Equilibrium |
Balance voltage for single cell |
3.60V±25mV |
Balance current for single cell |
144±10 mA |
9 |
Resistance |
Inner resistance |
≤20mΩ |
10 |
Temperature |
Operating temperature range |
-40~+85°C |
Storage temperature range |
-20~ +125°C |
11 |
Size (L*W*T) |
L120mm*W80mm*T15mm |